- Apr 09 Fri 2010 23:34
-
Twin - Block Modified
- Apr 08 Thu 2010 16:51
-
Modified Tandem Appliances Class III 上下顎牽引裝置
Modified Tandem Appliance (MTA) 是設計作為治療 生長發育期中的Class III 患者. 這樣
的設計因為裝戴在口內較其他的裝置舒適,一般簡易的MTA包含三個部份一個上顎裝置(活
動或固定)一個下顎裝置固定或活動及一個牽引用的面弓。

|
|
photo by Dynaflex®
- Mar 10 Wed 2010 23:53
-
Teuscher Activator

Teuscher Activator
適用: Class II ,
增加口外牽引
H.G.Tube及 Torquing spring 扭力彈線壓於上顎前牙齒頸部,適用上顎前牙過度舌傾斜患者
- Mar 10 Wed 2010 23:37
-
Activator for class II
- Mar 10 Wed 2010 23:26
-
Functional Regulators
- Jan 21 Thu 2010 15:21
-
construction bite for functional appliances -activator ,bionator,frankel,TAP3

一般牙醫師較少製作功能性矯正裝置、止鼾器......對於製作用咬腊難免較不順手
1.請先確定功能性裝置,您所要的上下顎前後及垂直位置一般為edge t o edge open 2mm,或為將來(前後overjet及垂直overbite)需要調整的量,(A-P改變太大,下巴向前量太多可分兩次製作,以免病人過於酸痛不戴)
- Jan 13 Wed 2010 17:11
-
chin cap for reverse head-gear 半手製版
- Jan 13 Wed 2010 11:12
-
Twin Block functional appl.& fixed orthodontic

這個case 固定裝置已經黏上去,並矯正做到一定程度了,接下來配合Twin Block來治療,就如
activator....一般先將牙弓排列再裝戴功能性矯正裝置,Clasp主要用ball clasp
Frontal
- Aug 27 Thu 2009 17:36
-
Functional Mandibular Advancer (FMA)
Functional Mandibular Advancer (FMA)
Functional Mandibular Advancer (FMA)* for the non-compliance correction of Class II malocclusion
With the Functional Mandibular Advancer (FMA) a newly fixed and rigid appliance for the non-compliance correction of Class II discrepancies has been developed.
Essential elements of this Herbst alternative are protrusive bars and inclined planes, which are fixed on cast splints or bands on the vestibular sides of the posterior teeth.
For more information and case-studies please download our infosheet as PDF.
*according to PD Dr. G. Kinzinger and Dr. J. Ostheimer
(FMA)
With the Functional Mandibular Advancer (FMA) a newly fixed and rigid appliance for the non-compliance correction of Class II discrepancies has been developed.Essential elements of this Herbst alternative are protrusive bars and inclined planes, which are fixed on cast splints or bands on the vestibular sides of the posterior teeth.
For more information and case-studies please download our infosheet as PDF.
*according to PD Dr. G. Kinzinger and Dr. J. Ostheimer
Functional Mandibular Advancer (FMA)* for the non-compliance correction of Class II malocclusion
With the Functional Mandibular Advancer (FMA) a newly fixed and rigid appliance for the non-compliance correction of Class II discrepancies has been developed.
Essential elements of this Herbst alternative are protrusive bars and inclined planes, which are fixed on cast splints or bands on the vestibular sides of the posterior teeth.
For more information and case-studies please download our infosheet as PDF.
*according to PD Dr. G. Kinzinger and Dr. J. Ostheimer
- Apr 29 Wed 2009 16:45
-
Bite jumping screw*for the modified Twin Block appliance.

這是FORESTADENT一個增加TWIN -BLOCK下顎前凸量的附件,在很久以前就知道這附件,一直到有一醫師交給我在其所做的TWIN-BLOCK加上,不知道一組多少錢,應該問一下傑基公司。
這裡是動畫看了就知道 英文就不翻了
再看一下這裡你就完全懂了
- Mar 19 Thu 2009 16:36
-
Expansion Activor